E-NTU Method (Effectiveness – N TU method). Note, in most heat exchanger design problems, we don’t. know the fluid outlet temperatures, ie. Tiour or Tribut. TA. Summary of lmtd and e ntu. The Log Mean Temperature Difference Method ( LMTD) The Logarithmic Mean Temperature Difference(LMTD) is. Q: What is the real difference between the LMTD (logarithmic mean temperature difference) and NTU (number of transfer units) methods for analyzing heat.

Author: Vill Arashit
Country: Lithuania
Language: English (Spanish)
Genre: Art
Published (Last): 7 September 2006
Pages: 236
PDF File Size: 3.84 Mb
ePub File Size: 17.24 Mb
ISBN: 920-9-67613-683-5
Downloads: 48124
Price: Free* [*Free Regsitration Required]
Uploader: Mazujora

Resolved comments Export to PDF. The required thermal capacity UA needed to achieve the heat transfer rate established by the temperatures and flow rates is calculated from the Heat Transfer Rate and the Corrected Mean Temperature Difference. The method proceeds by calculating the heat capacity rates i. From Wikipedia, the free encyclopedia.

Evaluating both the hydraulic and thermal conditions of a system can be a daunting task for any engineer and is often divided into different groups who specialize in a specific field. Therefore the effectiveness is given by: Similarly, a heat exchanger is sized and selected to meet the thermal requirements of the system, which includes the design heat transfer rate at a true mean temperature difference across the heat exchanger.

Resulting in less heat transfer and higher outlet fluid temperatures, which leads to off-quality production, exceeding environmental limits, or creating safety hazards that require mitigation.

NTU method – Wikipedia

The thermal capacity of the heat exchanger will match the thermal capacity required by the process conditions temperatures and flow rates if it has sufficient heat transfer area to do so. Fundamentals of Momentum, Heat and Mass Transfer.

The heat exchanger will operate at this thermal capacity as long as it has sufficient heat transfer area at these operating conditions, including a factor for fouling.

It is a function of the heat exchanger design and the fluid properties on both sides. For example, for a pure single pass counter current flow heat exchanger:.

The equation to calculate the heat transfer rate is given by: To understand the ljtd between these two methods, we need to understand the key terminology and the equations used in each solution method.

NTU method

The division often results in misunderstanding, miscommunication, and mistakes when integrating the work of the various groups.

  KORG AX1G MANUAL PDF

The HCR of a fluid is a measure of its ability to release or absorb heat. Corrective action would require the purchase and installation of a properly sized heat exchanger, causing additional downtime for installation. For example, for a pure single pass counter current flow heat methos Engineered Software Knowledge Base.

Piping systems are built to transport fluid to do work, transfer heat, and make a product. The relationship between these three parameters depends on the type of heat exchanger and the internal flow pattern. The control valve is slightly over-sized to ensure sufficient capacity to deliver the required flow. The Temperature Effectiveness P is the ratio of the tube side temperature change to the maximum temperature difference across ntj heat exchanger.

If the selected heat exchanger is undersized, the design heat transfer conditions will not be achieved. Some manufacturers provide a CF data table for their heat exchanger while others determine CF using a standard graph from the Tubular Exchanger Manufacturers Association TEMA for the actual heat exchanger configuration.

A control valve is sized and selected to meet the hydraulic requirements of the piping system, which includes the design flow rate and pressure drop across the valve.

Improperly sized equipment, whether the equipment is a pump, control valve or heat exchanger, results in additional capital and maintenance costs, off-quality production, environmental excursions, and potentially increase safety risks.

The other fluid would change temperature more quickly along the heat exchanger length. Wiley, New York F. Similarly, a direct comparison can be made between the thermal capacity of a heat exchanger and the flow capacity of a control valve. Effectiveness is dimensionless quantity between 0 and 1.

Engineering Analogies Analogies are often made between concepts in many engineering disciplines. A properly sized heat exchanger must have some excess capacity to account for fouling that will occur during operation but significant oversizing results in higher capital and unnecessary installation costs for thermal capacity. These relationships are differentiated from one another depending on the type of the flow counter-current, concurrent, or cross flowthe number of passes in shell and tube exchangers and whether a flow stream is mixed or unmixed.

Powered by Atlassian Confluence 6. Hence in this special case the heat exchanger behavior is independent of the flow arrangement. For this configuration, the Maximum Effectiveness for a given HCRR curve is greater than that for a pure single pass parallel flow configuration. The HCR is calculated for both fluids as the product of the mass flow rate times the specific heat capacity of the fluid.

  DICCIONARIO DE CIENCIA POLITICA NORBERTO BOBBIO PDF

Both methods share common parameters and concepts and will arrive at the same solution to heat exchanger thermal capacity. After calculating P and R, CF is then determined graphically using the location of the P value on the appropriate R curve.

For example, the effectiveness of a parallel flow heat exchanger is calculated with: When designing piping systems to support heat transfer between fluids, both the hydraulic and thermal conditions must be evaluated to ensure the proper equipment is selected and installed. Each HCRR curve flattens to a maximum value of Effectiveness as was the case for the pure single pass parallel flow heat exchanger. Voltage drop, current, and electrical resistance are analogous to pressure drop, fluid flow, and hydraulic resistance, which are analogous to the temperature difference, heat transfer rate, and thermal resistance.

Therefore the effectiveness is given by:. Analogies are often made between concepts in many engineering disciplines. The thermal capacity of a heat exchanger is its ability to transfer heat between two fluids at different temperatures. The Configuration Correction Factor CF accounts for the deviation of the internal flow pattern of the actual heat exchanger from that of a single pass counter current flow pattern.

The thermal capacity UA required to achieve the heat transfer rate is determined by re-arranging the NTU equation after determining the value of NTU for the particular heat exchanger configuration.

Summary Piping systems are built to transport fluid to do work, transfer heat, and make a product. The HCRR is limited to values between 0 and 1. Lavine Fundamentals of Heat and Mass Transfer ,6th edition, pp — The Effectiveness-NTU method takes a different approach to solving heat exchange analysis by using three dimensionless parameters: The NTU is a function of the Effectiveness and HCRR established by the process temperatures and flow rates and is indicative of the size of the heat exchanger needed.

P is limited to values between 0 and 1.